Docs
test1test2
6.5
6.5
  • ElastiFlow Documentation
  • Unified Flow Collector
    • General Configuration
    • Changelog
    • Maxmind GeoIP2 and GeoLite2
    • RiskIQ PassiveTotal
    • Network Interfaces
    • User-Defined Metadata
    • Docker
    • Linux
    • Unified Flow Collector Introduction
    • System Requirements
    • Supported IEs
    • AWS VPC Flow Log IEs
    • IPFIX IEs
    • Netflow IEs
    • sFlow IEs
  • Unified SNMP Collector
    • Device Groups
    • Changelog
    • Devices
    • Downloading Definitions
    • Enumerations
    • Objects
    • Object Groups
    • User-Defined Metadata
    • Docker
    • Network Interfaces
    • United SNMP Collector Introduction
    • Linux
    • Scheduling Rediscovery
  • Monitoring ElastiFlow
    • Liveness & Readiness
    • Metrics
    • Prometheus & Grafana
  • Configuration Reference
    • YAML Configuration Files
    • Configuration Reference Overview
    • Common
      • API
      • Licensing
      • Overview
      • Logging
      • HTTP output
      • Elasticsearch output
      • Kafka output
      • Monitor output
      • OpenSearch output
      • Splunk output
      • stdout output
      • Processor
    • Unified Flow Collector
      • Overview
      • Community/Conversation IDs
      • EF_PROCESSOR_ENRICH_TOTALS_IF_NO_DELTAS
      • Overview
      • RiskIQ PassiveTotal
      • Maxmind
      • User-Defined Metadata
      • Overview
      • Overview
      • User-Defined Metadata
      • Overview
      • Benchmark Input
      • Netflow/IPFIX/sFlow (UDP)
      • Licensing
      • Decoder/Processor
      • Sample Rate
      • Configuration Changes
    • Unified SNMP Collector
      • User-Defined Metadata
      • Overview
      • Licensing
      • SNMP Poller
      • EF_PROCESSOR_SNMP_ENUM_DEFINITIONS_DIRECTORY_PATH
  • API Reference
    • API Reference Overview
    • SNMP Operations
  • Data Platforms
    • Elastic
      • Basic Cluster
      • Advanced Cluster
      • Single Server
      • Multi-Tier Cluster
      • Single "Lab" Server
      • Elasticsearch
      • ElastiFlow vs. Filebeat and Logstash
      • RHEL/CentOS
      • Ubuntu/Debian
      • Kibana
      • ML
        • Network Security
        • Machine Learning
        • Availability
          • Network Availability
          • DHCP
          • LDAP
          • DNS
          • NTP
          • RADIUS
          • TCP Sessions
        • Network Security Activity
          • Rare Autonomous System
          • Network Activity
          • Rare Conversation
          • Rare Geolocation
        • Network Security Brute Force
          • Brute Force CLI Access
          • Brute Force Remote Desktop Access
          • Brute Force Attacks
        • Network Security DDoS
          • Denial-of-Service
          • ICMP Flood Attack
          • SYN Flood Attack
          • TCP DDoS Attack
          • UDP Amplification Attack
        • Network Security Recon
          • ICMP Scan
          • Reconnaissance
          • Port Scan
        • Performance
          • Unusual ASN Traffic Volume
          • Unusual Network Interface Traffic Volume
          • Network Performance
    • Opensearch
      • Dashboards
      • Auth Sig V4
    • Splunk
      • Default Search Macro
      • Configuring Data Input & Index
      • Splunk App Installation
    • Output Configuration
  • Additional Guides
    • Catalyst (sFlow)
    • FortiGate
    • hsflowd
    • Configuring Flow Sampling on Juniper Routers
    • Junos OS (sFlow)
    • MikroTik RouterOS
    • OpenWRT (softflowd)
    • Ubiquiti EdgeRouter
    • SonicWall
    • Junos OS
    • Extending SNMP Device Support
    • Flow Device Support Overview
    • SNMP Device Support Overview
    • Generating A Support Bundle
  • FAQ
    • Flows stopped showing up in Kibana (Disk(s) Full)
    • Common reasons why you have discrepancies between ElastiFlow data & reality
    • What Are Snapshots?
    • Importing the wrong dashboards (No data)
  • Knowledge Base
    • Config
      • Elasticsearch Authentication Failure
      • CA Certificate Path Incorrect
      • license/error Invalid Segments
    • Flow
      • Bidirectional Flow Support
      • Configure the UDP Input
      • Flow Records Not Received
      • Netflow v9/IPFIX Template Not Receieved
      • Unsupported sFlow Structures
    • General
      • License Has Expired
      • License Agreement Not Accepted
    • Install
      • .deb Upgrade Fails File Overwrite
    • Operation
      • Flow Collector Queues 90% Full
      • Dashboard Updates
      • Change elastiflow-* Index Name?
  • Elastic Stack Deployment
  • Download Links
Powered by GitBook
On this page
  • Access the switch CLI
  • Enter configuration mode
  • Configure SNMP settings
  • Configure SNMPv3 (optional)
  • Commit and save the changes
  • Exit configuration mode
  • Verify the configuration
  1. Additional Guides

Junos OS

To configure SNMP on a Juniper Junos device, follow these steps:

Access the switch CLI

Connect to your Juniper EX switch via SSH or a console cable. If connecting via SSH, use a tool like PuTTY or the built-in SSH client in your terminal, and enter the switch's IP address, username, and password to log in.

Enter configuration mode

Once logged in, enter configuration mode by typing the following command:

configure

Configure SNMP settings

a. To configure the SNMP community string, use the following command:

set snmp community COMMUNITY_STRING_NAME authorization read-only

Replace COMMUNITY_STRING_NAME with the desired SNMP community string (e.g., public).

b. To restrict SNMP access to specific IP addresses or networks, use the following command:

set snmp community COMMUNITY_STRING_NAME clients x.x.x.x/y

Replace COMMUNITY_STRING_NAME with the SNMP community string you previously defined, and x.x.x.x/y with the IP address or network CIDR (e.g., 192.168.1.0/24).

c. To configure the SNMP system contact, location, and description, use the following commands:

set snmp contact "CONTACT_INFORMATION"
set snmp location "DEVICE_LOCATION"
set snmp description "DEVICE_DESCRIPTION"

Replace CONTACT_INFORMATION, DEVICE_LOCATION, and DEVICE_DESCRIPTION with the appropriate information for your switch.

Configure SNMPv3 (optional)

If you want to use SNMPv3 for increased security, you can configure SNMPv3 settings as follows:

a. To create an SNMPv3 user, use the following command:

set snmp v3 usm local-engine user SNMPv3_USER_NAME authentication-md5 authentication-password SNMPv3_AUTH_PASSWORD privacy-des privacy-password SNMPv3_PRIV_PASSWORD

Replace SNMPv3_USER_NAME, SNMPv3_AUTH_PASSWORD, and SNMPv3_PRIV_PASSWORD with the desired SNMPv3 username, authentication password, and privacy password, respectively.

b. To configure the SNMPv3 user access, use the following command:

set snmp v3 vacm security-to-group security-model usm security-name SNMPv3_USER_NAME group SNMPv3_GROUP_NAME

Replace SNMPv3_USER_NAME with the SNMPv3 username you previously defined, and SNMPv3_GROUP_NAME with a desired group name for this user (e.g., snmpv3group).

c. To configure the SNMPv3 group access, use the following command:

set snmp v3 vacm access group SNMPv3_GROUP_NAME default-context-prefix security-model usm security-level privacy read-view all

Replace SNMPv3_GROUP_NAME with the SNMPv3 group name you previously defined.

Commit and save the changes

After configuring the SNMP settings, commit and save the changes by entering the following commands:

commit
save

Exit configuration mode

Type exit to leave configuration mode and return to the Juniper EX switch CLI.

Verify the configuration

To verify that SNMP is configured correctly, use the following command:

show snmp

This command should display the SNMP settings you just configured.

Once you've completed these steps, your Juniper Junos device will be configured for SNMP monitoring. Ensure your ElastiFlow Unified SNMP Collector is set up to communicate with the device using the appropriate SNMP community string or SNMPv3 credentials. This will allow you to monitor the devices's performance and gather statistics. Remember to follow best practices for SNMP security, such as using SNMPv3 with encryption and authentication, restricting SNMP access to specific IP addresses or networks, and regularly updating SNMP community strings or credentials.

PreviousSonicWallNextExtending SNMP Device Support